HP BladeSystem c3000 Enclosure - Rack - Front View
HP BladeSystem c3000 Enclosure - Rack - Rear View
1.
Device Bays 1 thru 8
1.
Local KVM interface
2.
Enclosure DVD Drive
2.
Interconnect Bay 1
3.
Standby Onboard Administrator
3.
Active Cool 100 Fans and fan bays
4.
Insight Display
4.
Interconnect Bay 2
5.
Active Onboard Administrator
5.
Enclosure Up-link and Service Port
6.
Enclosure Down-link
7.
iLO/Onboard Administrator Port
8.
iLO/Onboard Administrator Port 2 (reserved for future)
9.
Power Supplies
10.
Interconnect Bay 4
11.
Interconnect Bay 3
A HP BladeSystem solutions start with a either a c7000 or c3000 Enclosure. For the c3000 Enclosure, customers can add c3000 hot-
plug power supplies, HP Active Cool Fans, and an optional redundant BladeSystem Onboard Administrator module. Once the enclosure
has been selected, the following components can be added: networking interconnect modules, HP ProLiant and Integrity Server Blades,
expansion blades, and optional Insight Control for BladeSystem management software. For information on these options please visit:
http://www.hp.com/go/bladesystem
.
A BladeSystem c3000 enclosure holds up to 8 server and/or storage blades plus redundant network and storage interconnects. It
includes a shared, multi-terabit high-speed mid-plane for wire-once connectivity of server blades to network and shared storage.
Power is delivered through a pooled power backplane that ensures the full capacity of the redundant hot-plug power supplies is
available to all blades.
HP BladeSystem c3000 enclosure options:
A single-phase enclosure available worldwide for use with in-rack PDUs & UPSs which accept C13/C14 power cords; or "
Alternatively, in countries with low-line (100VAC to 110VAC) power outlets, the enclosure's power supplies can be connected
directly to low-line wall outlets.
NOTE:
Caution: when connecting directly to wall outlets, customers should determine the maximum amperage of the wall outlet
circuit to prevent power overload. See the Technical specification section later in this document for the individual power supply
amperage.
QuickSpecs
HP BladeSystem c3000 Enclosure
Overview
DA - 12790 Worldwide — Version 56 — February 18, 2014
Page 1
Zobrazit stránku 0
1 2 3 4 5 6 ... 32 33

Shrnutí obsahu

Strany 1 - QuickSpecs

HP BladeSystem c3000 Enclosure - Rack - Front ViewHP BladeSystem c3000 Enclosure - Rack - Rear View1.Device Bays 1 thru 81.Local KVM interface2.Enclos

Strany 2

HP BladeSystemc-Class Server BladeEnclosuresNOTE: HP does not allow factory integration of options into pre-configured models. Any additional optionsp

Strany 3

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Strany 4

power supply options you have selected can fully support your BladeSystemconfiguration. The HP Power Advisor tool can be downloaded atwww.hp.com/go/hp

Strany 5

Cisco Catalyst 1GbE 3120G Blade Switch451438-B21Cisco Catalyst Blade Switch 3020 for HP c-Class BladeSystem410916-B21HP Cisco B22HP Fabric Extender fo

Strany 6

Step 5: Select Wall Outlet Power Cords (For connection to standard wall outlets)NOTE: Select one wall outlet power cord for each power supply when plu

Strany 7

HP c3000 EnclosureOptionsHP c-Class BladeSystem Miscellaneous Blanks Option Kit412148-B21NOTE: Contains 1 each of c3000/c7000 Active Cool Fan blank, c

Strany 8

HP c-Class Power SupplyNOTE: HP BladeSystem Power supplies meet multiple Energy Efficiency Initiatives:1200W, Climate Savers Computing Initiative SILV

Strany 9

HP BladeSystemc-Class FC SANInterconnectsHP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem466482-B21HP Virtual Connect 8Gb 2

Strany 10

http://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.html(Worldwide)HP iLO Advanced forBladeSystem LicenseHP iLO Advanced for BladeSystem

Strany 11

HP Ultrium Tape BladesHP StoreEver LTO-5 Ultrium SB3000c Tape BladeBS580BHP StoreEver LTO-4 Ultrium SB1760c Tape BladeAQ697BNOTE: Please see the Quick

Strany 12

HP 1200W Common Slot Platinum Hot Plug Power Supply Kit (up to 6 total); orHP 1200W Common Slot -48VDC Hot Plug Power Supply Kit (up to 6 total)c-Clas

Strany 13

NOTE: Please see the following QuickSpecs for additional options including shorterjumper cables and country specific power cords:http://h18000.www1.hp

Strany 14

NOTE: Please see the QuickSpecs for additional information:http://h18000.www1.hp.com/products/quickspecs/14058_div/14058_div.html(Worldwide) R5000 Uni

Strany 15

HP 800VA - 277V Input / 230V Output NA Rack Mount TransformerH3X09ANOTE: Please see the QuickSpecs for Technical Specifications and additionalinformat

Strany 16

HP TFT7600 G2 KVM Console Rackmount Keyboard DK MonitorAZ876AHP TFT7600 G2 KVM Console Rackmount Keyboard NO MonitorAZ877AHP TFT7600 G2 KVM Console Ra

Strany 17

NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/12662_div/12662_d

Strany 18

HP 1200W Common Slot Platinum Hot Plug Power Supply KitPart Number500172-B21Input Voltage Range ( V rms )100-240Frequency Range (Nominal) ( Hz )50 / 6

Strany 19

HP 1200W Common Slot -48VDC Hot Plug Power Supply KitPart Number437573-B21Input Voltage Range ( V rms )36-72Frequency Range (Nominal) ( Hz )DCNominal

Strany 20

Fan & power supply bay numberingRack power supply bay numberingFan bay numbering Power supplies and fans must be placed in the following baysNumbe

Strany 21

The c3000 enclosure is divided into 2 zones by the horizontal support metalwork. The lower zone (zone 1) includes bays 1, 2, 5, and 6.The upper zone (

Strany 22

1.2.3.4.5.Full-height server blade bay numberingHP BladeSystem c3000 Enclosure – Racks1.Device Bay 12.Device Bay 23.Device Bay 34.Device Bay 4NOTE: Fu

Strany 23

HP BladeSystem c-Classc3000 EnclosureA BladeSystem c3000 enclosure holds up to 8 server blades and up to 4 expansion blades (not exceeding 8total blad

Strany 24

1.2.3.1.2.3.4.5.6.7.Expansion bladesExpansion blades consist of storage blades, tape blades, and the PCI Expansion Blade. Up to 4 expansion blades are

Strany 25

Enclosure Unit –Rack ModelDimensions (H x W x D)(with bezel)10.4 x 19.1 x 32.977 in (265 x 485 x 835 mm)Weight(approximate)Maximum(one enclosure with

Strany 26

AltitudeOperating3050 m (10,000 ft). This value may be limited bythe type and number of options installed.Maximum allowable altitude change rate is 45

Strany 27

© Copyright 2014 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows N

Strany 28

Lower power consumption, in comparison to rack-mounted servers.Service and management: Allows multiple administrators to remotely access and maintain

Strany 29

HP BladeSystem c-ClassInterconnect OptionsHP offers one of the broadest selections of interconnect fabric options in the industry to provide network,S

Strany 30

Insight Management software media is available for free download (notincluding license entitlement certificates) at this website:http://www.hp.com/go/

Strany 31

delivery of software updates. For more information about this service, pleasevisit: http://www.hp.com/services/insightHP Matrix OperatingEnvironmentTh

Strany 32

Service and SupportHP Technology Services for Industry Standard Servers and BladeSystemCapitalizing on HP ProLiant server and HP BladeSystem capabilit

Strany 33

blades and HP Insight Control, plus Server Deployment (formerly RDP).http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA0-5964ENW.pdfHP Installation and Star